Repair

Siemens repair in Aarhus

We repair Siemens fully automatic coffee machines in our workshop in Tilst — including the EQ series.

Siemens' EQ series is among the best-selling fully automatic coffee machines in Denmark, and we see them regularly in the workshop. Typical problems are a brew group that jams, leaks, or error codes on the display — all things we can diagnose and repair.

Models we repair

  • Siemens EQ 300
  • Siemens EQ 700 TQ707R03/02
  • Siemens EQ6 Plus
  • Siemens EQ6 Plus S500
  • Siemens EQ6 Plus S700
  • Siemens EQ6 S100
  • Siemens EQ9
  • Siemens EQ9 S300
  • Siemens EQ9 S900
  • Siemens EQ9 connect s900
  • Siemens iQ700 CT636LES1/01
  • Siemens iQ700 CT636LES1/05 built-in

Common faults on Siemens machines

See all known faults

What should you bring?

  • The machine itself, ideally with the water tank emptied
  • The power cable
  • A short description of the problem — feel free to email us beforehand

Real Siemens repairs

Siemens EQ5 macchiato plus

Siemens EQ5 macchiato plus

Problem: Machine constantly displayed 'Descale now' even after descaling and the brew unit was blocked.
Solution: Scale sensors replaced, brew unit cleaned and lubricated. Descaling program reset and verified.
See the case

Siemens EQ6 / EQ6 Plus S100

Problem: A faulty ceramic valve, plus a separate machine that only produced cold coffee despite a working heater.
Solution: The ceramic valve was replaced on one unit. On another, the main board was identified as the cause of the cold coffee and replaced.
See the case

Siemens EQ6 Plus S700

Problem: Unusual noises at startup, intermittent faults and issues around the brew group.
Solution: The brew group was rebuilt/adjusted, and the machine was descaled and tested. On other S700 units, the ceramic valve and brew group were also serviced.
See the case

Siemens EQ9 S900

Problem: Water flow and brewing were affected by heavy scale in the ceramic valve.
Solution: The ceramic valve was cleaned and the water path checked.
See the case

Siemens EQ9 Plus Connect S700

Problem: The milk system wasn't working correctly.
Solution: The milk and water circuits were diagnosed and serviced.
See the case

Siemens EQ9 S300

Problem: Extensive faults in the water path and worn components.
Solution: The machine was serviced throughout, including the brew group, heater and ceramic valve.
See the case

Siemens EQ300

Problem: Several units with faults in the brew group, startup and front control panel.
Solution: The brew group was adjusted or rebuilt, and on another unit the touch/control board was replaced and the front panel serviced.
See the case

Siemens EQ6 Plus S300

Problem: A fault related to control/brew group on a used machine.
Solution: The main board and brew group were diagnosed with a view to rebuilding.
See the case

Siemens EQ6 Plus S500

Problem: Lukewarm coffee and unstable milk steam.
Solution: Control, heating and the water path were diagnosed; the machine was used to test compatible main boards and heater function.
See the case

Siemens EQ7

Problem: The grinder ran, but no water passed through the coffee.
Solution: The water path and brewing were diagnosed and the machine restored to service; on a later EQ7, the grinder and coffee outlet were also assessed.
See the case

Siemens CT636 / CTL636 Built-in

Problem: The machine wasn't producing coffee, gave dry grounds and faulted during startup.
Solution: The ceramic valve was replaced, and the small communication/translator board was replaced after extensive troubleshooting.
See the case
Siemens EQ 500

Siemens EQ 500

See the case

Frequently asked questions about Siemens

See all questions

Is your Siemens machine broken?

Contact us today for a non-binding quote. Diagnostics cost 400 kr. and are deducted from the repair price if you go ahead.

Contact us now

Cart (0)

Your cart is empty