Our work

Portfolio

A selection of machines we've saved. From simple gasket replacements to complex electronic repairs.

Jura Impressa J5
Bean-to-Cup

Jura Impressa J5

Problem: Machine started descaling but stopped halfway and showed E8 error. Coffee tasted bitter and weak.
Solution: Scale sensors cleaned, descaling program completed manually. Brew unit fitted with new seal.
De'Longhi Magnifica S Smart ECAM250.33.TB
Bean-to-Cup

De'Longhi Magnifica S Smart ECAM250.33.TB

Problem: Brew unit was stuck and could not be removed. Machine showed error code and stopped mid-brew.
Solution: Brew unit cleaned and lubricated, worn gears replaced. Descaled and thoroughly tested.
Sage SES880 BSS Barista Touch
Espresso Machine

Sage SES880 BSS Barista Touch

Problem: Touchscreen froze during milk steaming and the milk system produced cold foam.
Solution: Firmware updated, milk system cleaned and steam thermostat replaced. Includes new milk jug.
Sage BES875 BSS Barista Express
Espresso Machine

Sage BES875 BSS Barista Express

Problem: Grinder stopped grinding evenly and there was pressure drop during extraction — espresso ran too fast.
Solution: Conical burrs cleaned and adjusted. New seals in group head and portafilter. PID recalibrated.
Sage The Duo-Temp BES810 BSSUKM
Espresso Machine

Sage The Duo-Temp BES810 BSSUKM

Problem: Thermoblock was not heating to the correct temperature — espresso came out lukewarm.
Solution: Thermoblock descaled, new NTC temperature sensor fitted and PID regulation recalibrated.
Ascaso Dream M.F Red 2009
Espresso Machine

Ascaso Dream M.F Red 2009

Problem: Older machine with heavily scaled boiler and worn seals causing leaks during brewing.
Solution: Full service overhaul: new boiler gasket, descale, new pump seal and flush.
De'Longhi PrimaDonna Elite ECAM 650.55.MS
Bean-to-Cup

De'Longhi PrimaDonna Elite ECAM 650.55.MS

Problem: Milk system was not frothing properly and the touchscreen was responding slowly.
Solution: Milk system disassembled, cleaned and new valve fitted. Software reset and touchscreen calibrated.
Sage The Oracle BES980
Espresso Machine

Sage The Oracle BES980

Problem: Automatic tamping mechanism was out of calibration and the dual boiler was leaking internally.
Solution: Tamping motor and mechanism recalibrated. Boiler seals replaced. Full service overhaul.
Siemens EQ5 macchiato plus
Bean-to-Cup

Siemens EQ5 macchiato plus

Problem: Machine constantly displayed 'Descale now' even after descaling and the brew unit was blocked.
Solution: Scale sensors replaced, brew unit cleaned and lubricated. Descaling program reset and verified.
Saeco HD8914
Bean-to-Cup

Saeco HD8914

Problem: Coffee piston was stuck in the brew unit and the machine could not complete the brew cycle.
Solution: Brew unit disassembled, coffee piston and seal replaced. Ceramic grinder cleaned and calibrated.
Ariete 1324
Espresso Machine

Ariete 1324

Problem: Machine was building excessive pressure and leaking at the brew group. Cosmetic wear on the casing.
Solution: Replaced brew group gasket and O-rings. Full system clean and descale.
Nivona NICR 859 type 692
Bean-to-Cup

Nivona NICR 859 type 692

Problem: LatteRondello milk system was blocked and the brew unit had heavy coffee residue build-up.
Solution: Milk system disassembled and thoroughly cleaned. Brew unit degreased and new seal fitted. Descaled.
Sage The Oracle Touch SES990 BSS
Espresso Machine

Sage The Oracle Touch SES990 BSS

Problem: Touchscreen was unresponsive and the grinder stopped mid-grind — likely motor failure.
Solution: Touchscreen controller and grinder motor replaced. Full calibration of grinding and tamping.
Gaggia Brera Sup 037RG
Bean-to-Cup

Gaggia Brera Sup 037RG

Problem: Grinder was grinding unevenly and the brew unit was leaking coffee into the drip tray.
Solution: Ceramic burrs cleaned and adjusted. Brew unit seals replaced and machine descaled.
Milk Cooler

Jura Cool Control 591

Problem: The unit was missing its lid/power accessory.
Solution: The missing parts were identified, and the unit was worked on as a refurbishment project.
Sage Oracle Jet
Espresso Machine

Sage Oracle Jet

Problem: A blocked machine with restricted water flow.
Solution: The machine was taken in for diagnosis and cleaning of the water path.
Bean-to-Cup

Melitta Caffeo Varianza CSP

Problem: The machine dosed too little coffee and had milk frother issues.
Solution: The dosing mechanism was disassembled and inspected, the machine rebuilt, and the bean feed/dosing area cleaned and diagnosed.
Bean-to-Cup

Jura W10

Problem: A water leak at an internal connection.
Solution: A T-piece and a hose were replaced.
Bean-to-Cup

Siemens EQ6 / EQ6 Plus S100

Problem: A faulty ceramic valve, plus a separate machine that only produced cold coffee despite a working heater.
Solution: The ceramic valve was replaced on one unit. On another, the main board was identified as the cause of the cold coffee and replaced.
Capsule Machine

Nespresso C85

Problem: Slow/noisy operation and a missing water tank lid.
Solution: Pump/water flow and the missing parts were diagnosed.
Capsule Machine

Nespresso D112

Problem: Slow flow and an unstable milk frother.
Solution: The water flow and milk frother were reviewed and diagnosed.
Coffee Grinder

Fiorenzato E64

Problem: The grinder had mechanical issues around the doser/fork mechanism.
Solution: The relevant mechanical parts were replaced or assessed.
Coffee Grinder

Ascaso i-Steel i1

Problem: The grind setting was stuck on a very fine grind.
Solution: The fault was diagnosed.
Coffee Grinder

Aarke Coffee Grinder A1390

Problem: A used grinder was missing its collection cup.
Solution: The grinder was taken in for inspection.
Coffee Grinder

Baratza Sette 270

Problem: The grinder was noticeably noisy.
Solution: It was inspected as part of a sale/refurbishment process.
Bean-to-Cup

Siemens EQ6 Plus S700

Problem: Unusual noises at startup, intermittent faults and issues around the brew group.
Solution: The brew group was rebuilt/adjusted, and the machine was descaled and tested. On other S700 units, the ceramic valve and brew group were also serviced.
Bean-to-Cup

Melitta Barista TS / GT Smart

Problem: Blocked water path, faulty valves, and later a system fault during brewing.
Solution: The membrane regulator, outlet valve and 5-port ceramic valve were replaced. The brew group, drain valve and grinder were cleaned/serviced. On a return visit, a stuck bean selector was identified.
Bean-to-Cup

Siemens EQ9 S900

Problem: Water flow and brewing were affected by heavy scale in the ceramic valve.
Solution: The ceramic valve was cleaned and the water path checked.
Bean-to-Cup

Siemens EQ9 Plus Connect S700

Problem: The milk system wasn't working correctly.
Solution: The milk and water circuits were diagnosed and serviced.
Bean-to-Cup

Siemens EQ9 S300

Problem: Extensive faults in the water path and worn components.
Solution: The machine was serviced throughout, including the brew group, heater and ceramic valve.
Bean-to-Cup

Siemens EQ300

Problem: Several units with faults in the brew group, startup and front control panel.
Solution: The brew group was adjusted or rebuilt, and on another unit the touch/control board was replaced and the front panel serviced.
Bean-to-Cup

Siemens EQ6 Plus S300

Problem: A fault related to control/brew group on a used machine.
Solution: The main board and brew group were diagnosed with a view to rebuilding.
Bean-to-Cup

Siemens EQ6 Plus S500

Problem: Lukewarm coffee and unstable milk steam.
Solution: Control, heating and the water path were diagnosed; the machine was used to test compatible main boards and heater function.
Bean-to-Cup

Siemens EQ7

Problem: The grinder ran, but no water passed through the coffee.
Solution: The water path and brewing were diagnosed and the machine restored to service; on a later EQ7, the grinder and coffee outlet were also assessed.
Built-in Bean-to-Cup

Siemens CT636 / CTL636 Built-in

Problem: The machine wasn't producing coffee, gave dry grounds and faulted during startup.
Solution: The ceramic valve was replaced, and the small communication/translator board was replaced after extensive troubleshooting.
Bean-to-Cup

Bosch TES50221RW/10 (EQ5 platform)

Problem: An older bean-to-cup machine on the same platform as the Siemens EQ5 was taken in for diagnosis and refurbishment.
Solution: The machine was reviewed as a donor/refurbishment unit, with focus on the brew group, water path and electronics.
Espresso Machine

Sage Barista Pro SES878

Problem: Leaks, missing water/steam, and on other units low pressure or stopping during brewing.
Solution: The steam arm, hoses, seals, solenoid and heater have been repaired or replaced depending on the fault.
Espresso Machine

Sage Bambino Plus

Problem: The pump ran, but no water passed through during extraction.
Solution: The water path and heater were diagnosed; on one repair case, the heater was identified as needing replacement.
Espresso Machine

Sage Barista Express Impress

Problem: Machines with blockages in the water path.
Solution: The water path and brew circuit were cleaned and flushed.
Espresso Machine

Sage Barista Touch Impress

Problem: The grinder dosed too much coffee and overloaded the tamping mechanism.
Solution: The grinder and dosing were reassembled, reset and diagnosed with focus on correct dose and tamping.
Capsule Machine

Nespresso / Sage Creatista Plus

Problem: Blocked water path, a faulty hose, and on other units issues with descaling/operation.
Solution: The water path and hoses were repaired/cleaned, and control/interface components were diagnosed on other units.
Espresso Machine

Rancilio Silvia

Problem: No heat after several brews; the PID controller had a fault and the safety thermostat had tripped.
Solution: The safety thermostat was reset and the faulty SSR in the PID system replaced. Other Silvia units have also been refurbished with boiler and casing parts.
Espresso Machine

ECM Synchronika

Problem: The machine needed service around the pump and internal fittings.
Solution: The pump was rebuilt, fittings retightened, and the machine serviced throughout.
Espresso Machine

Profitec Pro 700

Problem: Unstable pressure, especially on the first shots, and issues with the fixed water connection.
Solution: A damaged OPV and a blocked 90° inlet fitting were identified and replaced.
Espresso Machine

Lelit Bianca

Problem: Several internal leaks and issues around the group/drain.
Solution: The brew group was rebuilt and missing/worn parts replaced. The drain valve and seals were subsequently adjusted to stop the leak.
Espresso Machine

Lelit Mara X PL62X

Problem: A machine taken in for review/refurbishment and later prepared for sale.
Solution: The machine was serviced, tested and prepared, including work around the group and water path.
Espresso Machine

Rocket Appartamento

Problem: The power switch was behaving inconsistently.
Solution: The machine was diagnosed with focus on the switch and power path.
Bean-to-Cup

De'Longhi Dinamica

Problem: Most of the water ended up in the drip tray instead of the coffee.
Solution: The upper piston unit was identified as the fault area and replaced/repaired.
Espresso Machine

Nuova Simonelli Oscar II

Problem: The machine was heavily blocked and had pressure/water path issues.
Solution: The water path was cleaned and the machine diagnosed; the OPV and a fitting were identified as relevant components.
Espresso Machine

Vibiemme Domobar Super HX

Problem: Portafilters could pop out of the group during brewing.
Solution: The group, gasket and mechanical fit were serviced and checked.
Espresso Machine

Vibiemme Domobar Piccolo

Problem: An older machine taken in for refurbishment and inspection.
Solution: The machine was reviewed, serviced and worked on as a refurbishment project.
Espresso Machine

BFC Azzurra 2013

Problem: An older espresso machine needing preparation and group service.
Solution: The group gasket, filters/baskets and brew group were prepared for testing and service.
Espresso Machine

La Pavoni Europiccola

Problem: An older lever machine needing a mechanical/electrical review.
Solution: Operation and the machine were reviewed and prepared as a refurbishment project.
Espresso Machine

Ascaso Steel Duo DU-15

Problem: A fault in the hot water circuit, water returning to the tank, and unusual noises.
Solution: The hot-water solenoid was repaired, the group gasket replaced, and the machine refurbished/tested.
Espresso Machine

Ascaso Dream M.F Yellow 2019

Problem: The machine was missing parts around the OPV and steam arm.
Solution: The machine was reviewed as a refurbishment project and the necessary valves/seals identified.
Espresso Machine

Ascaso Dream Black 2009

Problem: The brew head was blocked and seized.
Solution: The machine was taken in for disassembly, cleaning and refurbishment of the brew head.
Bean-to-Cup

Jura Z6

Problem: The grinder wasn't working correctly.
Solution: The grinder was rebuilt and adjusted.
Bean-to-Cup

Jura ENA 8

Problem: A damaged brew group on one machine and a faulty grinder on another.
Solution: The brew group was repaired/rebuilt, and on another ENA 8 the grinder was replaced.
Bean-to-Cup

Jura E8

Problem: Leaks, coffee in the drip tray, a 'no beans' fault, and wear in the brew group.
Solution: The brew group was rebuilt with a service kit, connections/hoses were repaired, and on another unit the grinder was diagnosed/replaced.
Bean-to-Cup

Jura S8

Problem: A leak during brewing and a need for major service.
Solution: A damaged 90° connector, hose clamp and brew group parts were serviced/replaced.
Bean-to-Cup

Jura Z8

Problem: Coffee partly ending up in the drip tray, and on another unit conflicting water/drip-tray faults.
Solution: The brew group was identified as the fault area on one machine; sensors and connections were diagnosed on another.
Bean-to-Cup

Jura ENA 4

Problem: No water passing through the machine.
Solution: The brew group was disassembled, cleaned and rebuilt, followed by descaling and filter service.
Bean-to-Cup

Jura E80

Problem: The machine needed service on both the brew group and grinder.
Solution: The brew group and grinder were rebuilt and serviced.
Professional Bean-to-Cup

Jura X6

Problem: The machine couldn't draw in water.
Solution: The water circuit and brew group were reviewed and serviced with a premium rebuild kit.
Professional Bean-to-Cup

Jura XJ9 Professional

Problem: A leak around the water tank/water supply.
Solution: The tank connection and relevant seals/connections were repaired.
Professional Bean-to-Cup

Jura GIGA X8 Professional

Problem: The machine kept asking to fill the system and had flow issues.
Solution: The machine was descaled and the water circuit serviced, with focus on flowmeters, membranes and the brew group.
Professional Bean-to-Cup

Jura GIGA X3 Professional

Problem: Water ended up in the drip tray and brewing was unstable.
Solution: The outlet valves and pump membrane were replaced, the flowmeter cleaned, and the brew group rebuilt.
Bean-to-Cup

Jura J8

Problem: Espresso-based drinks were interrupted and the machine made an unusual noise during rinsing.
Solution: The fault was traced to a damaged brew group, which was serviced/refurbished.
Bean-to-Cup

Jura ENA 3

Problem: The machine got stuck in an 'open/close valve' loop.
Solution: The pump, flowmeter, membrane and valve mechanism were systematically tested; the control board was suspected as the remaining fault.
Bean-to-Cup

Jura ENA Micro 9 Aroma+

Problem: A worn/damaged brew group, grinder and ceramic valve across different units.
Solution: The brew group was rebuilt on a refurbishment unit, while other parts were diagnosed and assessed for replacement.
Bean-to-Cup

Jura E60

Problem: The machine needed a rebuild of the grinder and water/brew system.
Solution: The grinder, O-rings, filter and other service components were reviewed as part of a full refurbishment.
Bean-to-Cup

De'Longhi PrimaDonna Class

Problem: Coffee wasn't coming out of the machine correctly.
Solution: The fault was traced to the flowmeter, which was serviced/replaced.
Bean-to-Cup

De'Longhi Magnifica S

Problem: Several units with missing water flow, weak function or drivetrain faults.
Solution: The pump, main board and drivetrain have been diagnosed on different machines; other Magnifica S units have been cleaned, descaled and serviced.
Espresso Machine

De'Longhi La Specialista Arte

Problem: A significant internal leak.
Solution: The valve/solenoid assembly and connections were diagnosed, and the relevant parts replaced during refurbishment.
Bean-to-Cup

De'Longhi PrimaDonna Soul ECAM610.75.MB

Problem: The machine showed 'water circuit empty' and couldn't brew correctly.
Solution: The fault was traced to the upper piston unit, and the machine was repaired around this area.
Espresso Machine

De'Longhi La Specialista Maestro

Problem: The steam function wasn't working.
Solution: The solenoid assembly and L-connector were replaced.
Espresso Machine

De'Longhi La Specialista Prestigio

Problem: The machine got stuck in the descaling process and was heavily contaminated inside.
Solution: The descaling process was completed correctly, and scale, coffee and blockages in the hoses/water path were removed.
Bean-to-Cup

De'Longhi Eletta Cappuccino Evo

Problem: The machine was completely dead and wouldn't start.
Solution: The machine was taken in for diagnosis of the power supply and electronics; this case was still in progress at the latest update.
Espresso Machine

De'Longhi Dedica EC685

Problem: A leak at the heater connection and missing/worn parts.
Solution: Connections and seals were diagnosed and the machine prepared/refurbished with the relevant spare parts.
Combi Coffee Maker

De'Longhi BCO421.S Combi

Problem: The machine was missing a few drip-tray parts, but the core function was intact.
Solution: The machine was function-tested and assessed for preparation with the missing parts.
Bean-to-Cup

De'Longhi Cappuccino FCAM23.460.W EX:4

Problem: The machine had missing parts and a fault in the drive system.
Solution: The machine was diagnosed as a refurbishment/donor unit, and the necessary casing and motor parts were identified.
Bean-to-Cup

Philips 5400 / EP5447

Problem: Too little drink in the cup, water in the drip tray, and milk/steam issues.
Solution: The drain valve was replaced on one unit, and on another the solenoid in the milk/steam system was replaced.
Bean-to-Cup

Philips 5490

Problem: Coffee leaked internally, the cup was only partly filled, and the temperature was low.
Solution: The drain valve and worn O-rings/connection at the brew group were replaced.
Bean-to-Cup

Philips EP2224

Problem: The grinder intermittently gave a 'no beans' behaviour despite beans in the hopper.
Solution: The grinder and coffee chute were cleaned and diagnosed; missing/worn parts were identified.
Bean-to-Cup

Philips EP3241

Problem: The machine couldn't steam/froth milk correctly.
Solution: The milk/steam circuit and related components were diagnosed and serviced.
Bean-to-Cup

Philips HD8821

Problem: A noisy pump and a need for brew group service.
Solution: The brew group was rebuilt/serviced, and the pump and missing parts were assessed.
Espresso Machine

Gaggia Classic

Problem: Older Gaggia Classic units taken in for review.
Solution: The machines were checked as service/refurbishment projects, with focus on the group, heater and water path.
Espresso Machine

Saeco Aroma SIN015X

Problem: The machine could produce steam but didn't send water to the brew head, and was missing casing parts.
Solution: The water path and brew head were diagnosed, and missing parts were identified.
Bean-to-Cup

Miele CM5310

Problem: Water went straight to the drip tray instead of the coffee outlet.
Solution: The drain valve was identified as the fault area and serviced/replaced.
Bean-to-Cup

Miele CM61

Problem: The machine needed service on the brew group and drain system.
Solution: The brew group was rebuilt and the drain valve replaced as part of the refurbishment.
Bean-to-Cup

Miele CM63

Problem: The machine worked, but needed preventive mechanical service.
Solution: The brew group and grinder were reviewed/cleaned as refurbishment work.
Bean-to-Cup

Miele CM5100

Problem: The machine was completely dead.
Solution: The power path and electronics were diagnosed as part of a refurbishment project.
Bean-to-Cup

Nivona CaféRomatica 626 Type 571

Problem: A worn brew group and issues around the grinder/coffee chute.
Solution: The brew group was rebuilt, and the grinder, coffee chute and missing parts were assessed for refurbishment.
Bean-to-Cup

Nivona NICR 960 CaféRomatica

Problem: The milk frother wasn't working.
Solution: The 3-way valve and piston at the heater were rebuilt, the brew head flushed, the machine reset, and the grinder cleaned/rebuilt.
Bean-to-Cup

Nivona NICR 821 Type 709

Problem: The machine was taken in as a refurbishment unit.
Solution: The machine was reviewed with focus on the brew group, water path and general service.
Professional Bean-to-Cup

WMF Presto

Problem: The machine was software-locked and subsequently needed board/configuration work.
Solution: The backup battery and service/configuration software were handled, the board was replaced/worked on, and the machine was reset and reconfigured.
Built-in Bean-to-Cup

AEG Built-in 4543

Problem: A leak to the drip tray and a fault related to brewing/water path.
Solution: The upper piston and relevant hoses/connections were identified as the fault area and serviced.
Built-in Bean-to-Cup

AEG KKK884500M

Problem: The machine started poorly, the motor burned out, and the pump/drivetrain faulted.
Solution: The motor and pump were replaced as part of the troubleshooting; the control board was then identified as the likely remaining fault.
Built-in Bean-to-Cup

Gaggenau Built-in Coffee Machine

Problem: The descaling program couldn't complete, and water came out beside the spout.
Solution: The water path and descaling circuit were diagnosed and serviced.
Bean-to-Cup

Smeg BCC12

Problem: An internal leak and a faulty 90° connector.
Solution: The machine was disassembled and refurbished; the faulty 90° connector and missing drip-tray parts were identified/replaced.
Espresso Machine

Smeg ECF01

Problem: A fault in the pump's anti-drip/safety valve.
Solution: The vibration pump's anti-drip valve was identified as a service point and replaced/prepared.
Espresso Machine

KitchenAid Artisan 5KES2102EOB

Problem: A fault in the heater/boiler and controls.
Solution: The boiler and control knob were identified as necessary spare parts during diagnosis.
Bean-to-Cup

Krups EA8261

Problem: The machine needed filter/service work and had a faulty spout part.
Solution: The water path and spout were diagnosed, and the necessary spare parts identified.
Espresso Machine

Krups XP4000

Problem: An older espresso machine taken in for inspection/refurbishment.
Solution: The machine was function-tested and worked on as a used refurbishment unit.
Bean-to-Cup

Krups EA81

Problem: A used machine taken in for diagnosis.
Solution: The machine was reviewed as a refurbishment/donor unit with focus on brewing and water function.
Bean-to-Cup

Krups Type 996

Problem: An older Krups machine taken in for diagnosis.
Solution: The machine was reviewed as a refurbishment/donor unit.
Capsule Machine

Caffitaly S33R.2

Problem: The machine was taken in for a functional check.
Solution: Core function was tested, and the machine was assessed as working.
Espresso Machine

Dualit DCM2

Problem: The machine was slow to draw in water during testing.
Solution: Water intake and pump function were checked as part of the refurbishment work.
Steamer

Dualit Cino Steamer

Problem: The machine was leaking.
Solution: The machine was disassembled and repaired/serviced around the leak.
Espresso Machine

Mesko MS4403

Problem: A used machine was taken in for a functional check.
Solution: The machine was tested and assessed as working.
Filter Coffee Maker

Moccamaster Technivorm KBG 2020

Problem: The machine was missing its water reservoir/lid but otherwise worked.
Solution: The missing reservoir parts were identified and the machine function-tested.
Espresso Machine

Breville Barista Max VCF126X

Problem: No water was coming out of the machine.
Solution: The water path and pump function were diagnosed.
Espresso Machine

Gastroback 42612

Problem: The machine was completely dead.
Solution: Power and electronics were diagnosed as a refurbishment project.
Capsule Machine

Nespresso Pixie C60

Problem: A used capsule machine was taken in for preparation.
Solution: The machine was tested and prepared for resale.
Sage Oracle Touch

Sage Oracle Touch

Repaired 40+ times by us

Sage Barista Pro

Sage Barista Pro

Repaired multiple times by us

De'Longhi Electra Cappuccino

De'Longhi Electra Cappuccino

Jura ENA 8 EB

Jura ENA 8 EB

Sage The Oracle BES980 BSS /I

Sage The Oracle BES980 BSS /I

Siemens EQ 500

Siemens EQ 500

Do you have a faulty machine?

We look at all types and brands. Contact us and describe the problem.

Contact us

Cart (0)

Your cart is empty